PURPOSE To measure the upper and lower tear menisci in patients with aqueous tear deficiency (ATD) dry eye by real-time optical coherence tomography (OCT) and to determine the most effective meniscus variables for the diagnosis of dry eye. METHODS Eyes of 48 pre-screened ATD patients were compared with those of 47 healthy subjects. Upper and lower tear menisci were imaged simultaneously by re...
PURPOSE This study was designed to determine the ability of ultra-high-resolution optical coherence tomography (UHR-OCT) to monitor tear meniscus volume after dry eye treatment with Restasis(®) (0.05% cyclosporine). METHODS UHR-OCT was used to image the upper and lower tear menisci (height and volume) in 14 consecutive dry eye patients at baseline. The treatment group was initiated on daily R...
PURPOSE To determine the repeatability of real-time optical coherence tomography (OCT) measurements of tear film thickness (TFT) and variables of tear film menisci. METHODS Forty eyes were imaged with a custom-built, real-time OCT to obtain heights, curvatures, and cross-sectional areas of upper and lower tear menisci simultaneously. The central TFT was indirectly determined as the difference...
Various shapes of congenital abnormalities of the meniscus have been reported. Among them, the double-layered meniscus is rare. This article describes a 22-year-old man with a double-layered lateral meniscus who reported right knee pain with no history of trauma. The double-layered lateral meniscus included both the upper and lower meniscus. The anterior and posterior edge of the upper meniscus...
Background: Meniscus tear is a common finding in patients with anterior cruciate ligament (ACL) injury and may affectthe natural history of the injury and the outcomes of treatment. In the current study, the characteristics of meniscus tearsin patients who underwent arthroscopic ACL reconstruction were investigated.Methods: The hospital records of 1022 patients were reviewed. ...
PURPOSE To measure the lower tear meniscus dynamics with Fourier domain-optical coherence tomography (FD-OCT) in keratoconus patients without dry eye findings to evaluate the effects of the corneal ectasia on lower tear meniscus parameters, and to determine the most affected meniscus variable from the corneal ectasia in keratoconus. METHODS Prospective, clinical study. Forty-one eyes of 25 ke...
AIMS To devise a method to measure tear meniscus curvature by a non-invasive specular technique. METHODS A photographic system was devised. The system consisted of a camera and an illuminated target with a series of black and white stripes oriented parallel to the axis of the lower tear meniscus. The target was mounted on a flash gun close to the objective of a Brown macrocamera and calibrate...
dry eye is the major contributor to computer vision syndrome. the reductions in the blink rate and amplitude have been considered as the possible mechanisms leading to this condition. the purpose of this study is to evaluate the changes in the lower tear meniscus heights and areas in the computer reading task, in dry eye subjects, with and without soft contact lenses. in this quasi-experimental...
Purpose. To use optical coherence tomography (OCT) to evaluate the effect of punctal occlusion on tear meniscus volume in dry eye patients. Methods. Occlusion of both upper and lower puncta with collagen plugs was performed on one eye each in 20 dry eye patients and 20 normal subjects. The upper and lower tear menisci were imaged simultaneously by real-time OCT before punctal occlusion and on d...
An image processing algorithm is developed for quantitative assessment of tear meniscus dynamics from continuous optical coherence tomography (OCT) measurements. Clinical utility of dynamic OCT tear meniscus measurement is assessed in studies of tear meniscus parameters. The results indicate that any apparent changes in the early post-blink phase meniscus parameters are essentially related to t...